| ALICE Calibration Requirements | ||||||||||||||||||||||||||||||||||||||||||||
| V0 OK July 06 | ||||||||||||||||||||||||||||||||||||||||||||
| Par # | Parameter | Data format/size per channel | Data size (Total) Bytes | Update freq | Source | Confirmed | Run type / Trigger type | # of required events/sampling rate | Processing level: sub-event or event | Results: FEE/Archive | Accessible by offline | Calib. Procedure in AliRoot | use case # | |||||||||||||||||||||||||||||||
| on FES | in OCDB | reference | ||||||||||||||||||||||||||||||||||||||||||
| 1 | gains | 32 bits (TBC) | 512[1] | 0 | Run | DAQ (on line data) * | yes | physics data * | at least 2000 L2 (TBC) | event and sub-event | DAQ FES / OCDB | yes | fall 2006 | 6 | ||||||||||||||||||||||||||||||
| 2 | pedestal means | 32 bits (TBC) | 512 | 0 | Run | DAQ (on line data) * | yes | physics data * | at least 1000 L2 (TBC) | event and sub-event | FEE and DAQ FES / OCDB | yes | fall 2006 | 6 | ||||||||||||||||||||||||||||||
| 3 | pedestal sigmas | 32 bits (TBC) | 512 | 0 | Run | DAQ (on line data) * | yes | physics data * | at least 1000 L2 (TBC) | event and sub-event | FEE and DAQ FES / OCDB | yes | fall 2006 | 6 | ||||||||||||||||||||||||||||||
| 4 | time gains | 32 bits (TBC) | 256[2] | 0 | Run | DAQ (on line data) * | yes | physics data * | at least 10000 L2 (TBC) | event | DAQ FES / OCDB | yes | Unknown | 1 | ||||||||||||||||||||||||||||||
| 5 | time offsets | 32 bits (TBC) | 256 | 0 | Run | DAQ (on line data) * | yes | physics data * | at least 10000 L2 (TBC) | event | possibly FEE and DAQ FES / OCDB | yes | Unknown | 6 | ||||||||||||||||||||||||||||||
| 2048 | 0 | |||||||||||||||||||||||||||||||||||||||||||
| * dedicated runs will be used for an initial calibration | ||||||||||||||||||||||||||||||||||||||||||||
| DCS access - offline has access only to DCS archive DB, curently no access to configuration DB | ||||||||||||||||||||||||||||||||||||||||||||
| DAQ - offline has access to raw data and DAQ logbook, but no acccess to LDC or GDC directly | ||||||||||||||||||||||||||||||||||||||||||||
| OCDB - Calibration parameters are stored in the Offline Calibration DB. The data used to calculate these parameters, the reference data, can also be optionally archived for later access from offline. | ||||||||||||||||||||||||||||||||||||||||||||